Support Center > Search Results > SecureKnowledge Details
R70.30 Known Limitations
Solution

This article lists all of the known limitations of R70.30.

This is a live document that may be updated without special notice. We recommend registering to our weekly updates in order to stay up to date. To register go to UserCenter > My Profile > My Subscriptions.

Important notes:

For more information on R70.30 see the R70.30 Release Notes and R70.30 Resolved Issues.

Visit our discussion forums to ask questions and get answers from technical peers and Support experts.
Popular forums:

 

ID Symptoms
Upgrades, Downgrades and Installation
00543650, 00544157 SmartView Tracker crashes when reinstalling R70.30.
Anti-Virus Integration
00550445, 00550897 The cpd process on R70.30 Security Management server crashes when Automatic update for Anti-Virus is enabled.
SecurePlatform
00591754 When SNMP is enabled on a channel bonding/IPv6 environment, /var/log/messages are filled with messages, such as:

snmpd[PID]: error on subcontainer 'ia_addr' insert (-1}

Refer to sk63060 for the fix.

00734057  VLAN interface does not come up when configured through SecurePlatform R70.30 WebUI.
00849337,
00851231,
00851260,
00855752 
smartctl provided for SecurePlatform VPN-1 Gateway R70.30 results in error messages 'scsi response fails sanity test'. 
00885936,
00894283,
00894284,
00894285,
00900197,
00908306,
01603080
GateD daemon might crash when Security Gateway is a part of a large OSPF environment.
Refer to sk105383.
General
00645564,
00650909
IPSO HA VRRP frequently crashes. 
00736523,
00738184,
00738186.
00738188 
SAM alert fails for HTTP-DOS attack. 
00589037,
00589587,
00622149,
00630114,
00631934,
00644868,
00645159,
00655589 
When there is no VPN tunnel between two gateways, the following command fails:
snmpwalk -v 2c -c public localhost 1.3.6.1.4.1.2620.500.9002.1.3.<IP address>
00632842,
00634704,
00637262,
00653589,
00658122
Previously installed Security policy name is incorrectly displayed in SmartView Monitor Alerts.
00747772,
00748181,
00748183,
00748185
It takes several minutes to the fw sam -M -nij all command to return an output.
00788941,
00815057
New certificates on the ICA cannot be revoked.
00853274,
00853798,
00853799,
00853800,
00857677,
00859676,
00885390,
00903026,
00936263,
01056437,
01056440,
01057695,
01060611,
01111724,
01118586,
01119306,
01119814,
01121955,
01129793
Security Gateway might crash upon policy installation after deleting some rules from the rulebase if 'Connection Persistence' is set to 'Keep all connections' in Security Gateway object.
Refer to Scenario 4 in sk103598.
01053424 Headline scheduled backup using FTP overwrites the last backup. 
Clustering & Acceleration (ClusterXL and SecureXL)
00734189,
00749712,
00749713,
00749714
It is not possible to configure the same IPv6 address in 3rd party cluster members topology.
Provisioning
00657204
The ModifyROBOInterface command does not work.
SmartConsole - Graphical User Interface
00589767
"Where used" is missing the "saved policies" tab for time objects.
00842292,
00843459,
00843457 
Not all positions and sizes of panes in SmartDashboard are saved. 
00528574 After establishing SIC or during policy verification, you might get an error message: "Incorrect reply from server. Command: private-db-dirty-check." The message can be ignored. See sk44508.
Event Management (Eventia Analyzer)
00622240, 00625639
MS Outlook 2007 does not show icons when getting emails sent from Analyzer.
00596411,
00625657 
MS Outlook 2007 does not display the colors panel on emails sent from Analyzer.
VoIP
00600562,
00609256,
00609258,
00743730
The MGCP traffic is dropped with "request connection is out of state" message.
VPN
01361432,
01362498,
01362506,
01362507,
01379840
VPN SSL Network Extender (SNX) portal does not load ActiveX when connecting with Internet Explorer 11. SNX will start only in Java.
This solution is about products that are no longer supported and it will not be updated

Give us Feedback
Please rate this document
[1=Worst,5=Best]
Comment