Support Center > Search Results > SecureKnowledge Details
Interface is shown as 'UNKNOWN' in the FW Monitor output on IPSO OS Technical Level
Symptoms
  • Interface is shown as 'UNKNOWN' in the FW Monitor output on IPSO OS.
    Example:
    UNKNOWN:o[60]: 10.207.122.250 -> 192.168.28.27 (ICMP) len=60 id=31283
Cause

Logical properties of an interface did not get filtered/updated correctly into the Check Point kernel.


Solution

To correct this, it is recommended to restart the Check Point services to allow Check Point kernel to capture and refresh all of the physical as well as the logical property attributes of the interfaces:

HostName[admin]# cpstop ; cpstart

 


 

Related solutions:

Imported from Nokia support database

Give us Feedback
Please rate this document
[1=Worst,5=Best]
Comment