Support Center > Search Results > SecureKnowledge Details
Raid diagnostic does not work on Smart-1 3050/3150/5050/5150 Technical Level
Symptoms
  • Raid diagnostic does not work on Smart-1 3050/3150/5050/5150
  • raid_diagnostic command will return sh: /bin/megaRaidStatus :No such file or directory
  • raid monitoring reports constant that raid is optimal
Cause
Missing symbolic link in Jumbo Hotfix starting from:
  • R81 Jumbo Hotfix Take 25
  • R80.40 Jumbo Hotfix Take 114

Solution

This problem was fixed. The fix is included in:

If you choose not to upgrade, Check Point can supply a Hotfix. Contact Check Point Support to get a Hotfix for this issue.
A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.
For faster resolution and verification, please collect CPinfo files from the Security Management Server and Security Gateways involved in the case.

Hotfix installation instructions:
Refer to sk168597 - How to install a Hotfix.

This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.

Give us Feedback
Please rate this document
[1=Worst,5=Best]
Comment