Support Center > Search Results > SecureKnowledge Details
Some appliances are missing in hardware tab in MDS environment of R80.40 SmartConsole Technical Level
Symptoms
  • On Multi-Domain (MDS) environment only, the newly added in R80.40 from JHF 45 3800, 6400, 6700, 7000, 16200, 16600HS, 28000 and 28600HS appliances are missing from the hardware tab in the domains



  • These new appliances appear in the additional_hardware.C file of the Global domain, but not on the domains.

    /var/opt/CPsuite-R80.40/fw1/conf/additional_hardware.C
    /var/opt/CPmds-R80.40/customers/*/CPsuite-R80.40/fw1/conf/additional_hardware.C

Cause
The file additional_hardware.C was not copied from the MDS to Domains. It happened because the Jumbo Hotfix MDS module's deployment_map file was missing that instruction.