The information you are about to copy is INTERNAL!
DO NOT share it with anyone outside Check Point.
Some appliances are missing in hardware tab in MDS environment of R80.40 SmartConsole
Technical Level
Solution ID
sk169354
Technical Level
Product
SmartConsole / SmartDashboard
Version
R80.40
OS
Gaia
Date Created
14-Sep-2020
Last Modified
05-Nov-2020
Symptoms
On Multi-Domain (MDS) environment only, the newly added in R80.40 from JHF 45 3800, 6400, 6700, 7000, 16200, 16600HS, 28000 and 28600HS appliances are missing from the hardware tab in the domains
These new appliances appear in the additional_hardware.C file of the Global domain, but not on the domains.
/var/opt/CPsuite-R80.40/fw1/conf/additional_hardware.C
/var/opt/CPmds-R80.40/customers/*/CPsuite-R80.40/fw1/conf/additional_hardware.C
Cause
The file additional_hardware.C was not copied from the MDS to Domains. It happened because the Jumbo Hotfix MDS module's deployment_map file was missing that instruction.