Below is a list of appliances officially approved for use with the Maestro solution.

Notes

  • For supported network cards, refer to the Appliance Accessories Guide.
  • For a list of supported transceivers, refer to sk92755: Compatibility of transceivers for Check Point appliances.
  • Although Dual-Port 10G cards (marked with asterisk * in the table below) cannot be ordered as a separate option, they are supported if purchased in a gateway bundle.
  • For all other models or combinations of models that are not listed below, contact your local Check Point office for assistance to submit an RFE.

Supported Security Appliance Models

Show / Hide this section

Enter the string to filter this table:

Model Supported In Supported Cards Special Notes
5600
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
For the R80.20SP version, we recommend R80.20SP Jumbo Hotfix Take 163 and higher
5800
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
For the R80.20SP version, we recommend R80.20SP Jumbo Hotfix Take 163 and higher
5900
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
 
6200
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
Base/Plus packages
6400
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
Base/Plus packages
6500
  • CPAC-2-10F-C*
  • CPAC-4-10F-6500/6800-C
Base/Plus/Turbo packages
6600
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
Base/Plus packages
6700
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
Base/Plus packages
6800
  • CPAC-2-10F-C*
  • CPAC-4-10F-6500/6800-C
  • CPAC-2-40F-C
Base/Plus/Turbo packages
6900
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
Base/Plus packages
7000
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
Base/Plus packages
13500
  • CPAC-2-10F*
  • CPAC-4-10F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 191 and higher
13800
  • CPAC-2-10F*
  • CPAC-4-10F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 210 and higher
15400
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
  • CPAC-2-100/25F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 121 and higher
15600
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
  • CPAC-2-100/25F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 163 and higher
16000
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
  • CPAC-2-100/25F
Base/Plus/Turbo packages
16200
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
  • CPAC-2-100/25F
Base/Plus packages
16600HS
  • Not applicable

16600HS appliance has two fixed 40G/100G downlink ports.

Refer to the appliance datasheet for details.

23500
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
  • CPAC-2-100/25F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 121 and higher
23800
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
  • CPAC-2-100/25F
 
23900
  • CPAC-2-10F-B*
  • CPAC-4-10F-B
  • CPAC-2-40F-B
  • CPAC-2-100/25F
For the R80.20SP  version, we recommend R80.20SP Jumbo Hotfix Take 105 and higher
26000
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
  • CPAC-2-100/25F
Base/Plus/Turbo packages
28000
  • CPAC-2-10F-C*
  • CPAC-4-10F-C
  • CPAC-2-40F-C
  • CPAC-2-100/25F
Base/Plus packages
28600HS
  • Not applicable

28600HS appliance has two fixed 40G/100G downlink ports.

Refer to the appliance datasheet for details.

Certified Combinations of Security Appliance Models in the Same Security Group

From R81.10, Maestro supports different Security Appliance models in the same Security Group.

The main purpose of the "Mix appliances" feature is to provide a solution for Maestro customers who use discontinued appliances series (End of Sale). These customers will be able to add newer supported appliances to the same Security Group with the discontinued appliances.

Only specific models are compatible to work together in the same Security Group. The supported combinations are based on several hardware specifications, such as number of CPU cores, HyperThreading, and others.

Important Note for R81.10 - You must disable the SMO Image Cloning in the Security Group before you assign an appliance of a model that is different than models of other appliances assigned in this Security Group (Known Limitation PMTR-71298).

The tables below show the supported combinations.