Upgrade of Security Management server fails
Symptoms
  • In some scenarios, Management Server upgrade may fail.

    >
  • The cpm.elg file shows following error:
    DATE TIME,PID INFO threat.schema_changes.MultipleThreatEmulationSchemaChanges 
    [main]: isChangeListElementOnGatewayRelevant relevant SPECIFIC_GW 
    07/01/19 18:37:14,780  INFO threat.schema_changes.MultipleThreatEmulationSchemaChanges [main]: handelForGatewayTeSettings: with id: f69600b4-2302-4850-8b85-87863cf00dab
      name:TESettings_4402D83D-10CC-4B74-AACB-0DB6755884F9
     emulationLocation:SPECIFIC_GW
     emulationGw:null
    
    DATE TIME,PID ERROR coresvc.internal.ObjectCrudSvcImpl [main]: new collection contains null as value, fieldPath: emulationGwList
    
    com.checkpoint.management.cpm.commands.SchemaChangesCommand.run(SchemaChangesCommand.java:120)
    com.checkpoint.management.cpm.Cpm.main(Cpm.java:184)
    DATE TIME,PID ERROR cpm.commands.SchemaChangesCommand [main]: Exception thrown during running schema changes command
    java.lang.RuntimeException: com.checkpoint.management.dleserver.DleServerException: Found a collection with null as value.
    at com.checkpoint.management.threat.schema_changes.MultipleThreatEmulationSchemaChanges.updateObjects(MultipleThreatEmulationSchemaChanges.java:55)
    at com.checkpoint.management.threat.schema_changes.MultipleThreatEmulationSchemaChanges.handelForGatewayTeSettings_aroundBody0(MultipleThreatEmulationSchemaChanges.java:15)
    
  • The gateway does not exist in the Database. The gateway ID is in the TE settings name, after the string “TESettings_” - TESettings_4402D83D-10CC-4B74-AACB-0DB6755884F9
Cause

Schema change failed due to invalid Threat Emulation settings related to non-existing gateways.


Solution
Note: To view this solution you need to Sign In .