Support Center > Search Results > SecureKnowledge Details
VRRP VRID number similar to ClusterXL Mac magic number causes VRRP Master/Master state Technical Level
Symptoms
  • Cluster_ID of 1 in ClusterXL causes VRRP VRID-1 Master/Master state, for example:

    • fw01> show vrrp
      VRRP State
          VRRP Router State: Up
          Flags: On,MonitorFirewall
          Interface enabled: 2
          Virtual routers configured: 2
              In Init state 0
              In Backup state 0
              In Master state 2
      fw02> show vrrp VRRP State VRRP Router State: Up Flags: On,MonitorFirewall Interface enabled: 2 Virtual routers configured: 2 In Init state 0 In Backup state 0 In Master state 2

    • [Expert@HostName:0]# cphaconf cluster_id get
      cphaconf cluster_id: 1
Cause

The MAC Magic also known as the Cluster_ID and VRRP RFC MAC can be the same causing a conflict within VRRP.


Solution