The information you are about to copy is INTERNAL!
DO NOT share it with anyone outside Check Point.
QoS rule with Time object is enforced one hour later\earlier than time configured after daylight saving
Technical Level
Solution ID
sk117893
Technical Level
Product
QoS
Version
R77.30 (EOL), R80.10 (EOL)
Date Created
05-Jun-2017
Last Modified
02-Oct-2018
Symptoms
QoS rule with Time object is enforced one hour later\earlier than time configured after daylight saving.
Cause
To calculate the current time, QoS use a parameter holding the time zone offset. This parameter is not updated after creation, so in case of changes it will be incorrect till recreation.