Support Center > Search Results > SecureKnowledge Details
Maximum number of VLAN and VAPs for Gaia Embedded Appliances Technical Level
Solution

The table below lists the limitations for VLAN and VAPs configuration on Gaia Embedded Appliances running R77.20.31 and up:

Appliance Number of LAN switch Ports VAPs (including main VAP) Loopback Interfaces Tag-based VLANs Maximum Internal Network Interfaces* Bridges
600 / 1100 8 4 16 Global Internal Interface limit 24 10
1200R 4 - 16 Global Internal Interface limit 28 10
730 / 750 / 1430 / 1450 6 4 16 48 122 10
770 / 790 / 1470 / 1490 / 910 16 4+4** 16 48 112 10
1530 / 1550 6 4 16 100 122 10
1570 / 1590 8 4+4** 16 100 120 10
1600 16 - 16 200 250 10
1800 18 - 16 200 248 10

* VAPs + Switches (Port-based VLANs) + Tag-based VLANs + VTIs + Loopback interfaces

** On wireless supported submodels there are 4 VAPs per Radio (5 Ghz and 2.4 Ghz)

 

Related Solution: sk31631 - What is the maximum number of interfaces supported by Check Point software?.

Applies To:
  • 01973498

Give us Feedback
Please rate this document
[1=Worst,5=Best]
Comment