During policy installation, SmartDashboard suddenly disconnects; after that Edge devices are not able to connect to this Service Center
Symptoms
  • During policy installation, SmartDashboard suddenly disconnects from Security Management Server / Domain Management Server.
    There are no error messages.

  • After the failed policy installation, Edge devices are not able to connect to this Service Center.
    Only after manual restart of SMS process resolves this issue.

  • After enabling the generation of core dump files per sk92764, core dump file was created for FWM process and for SMS process during policy installation.

  • FWM core dump file contains the following stack:

    #0  CCkpTableMgr::Initialize (...) at .../srvis/xpcom/xpATL/Atlbase.h
    #1  0x... in CCkpPrvtTableMgr::Initialize (...) at CPMITableMgr.cpp
    #2  0x... in CSrvDbMgr::OpenPrivateDB (...) at .../srvis/xpcom/xpATL/Atlbase.h
    #3  0x... in OpenDatabaseImpl(cpatlCComPtr<COpenDbOpq>) ()
    #4  0x... in OpenDatabase(void*) ()
    #5  0x... in ?? () from /opt/CPshrd-R77/lib/libComUtils.so
    #6  0x... in T_event_mainloop_iter () from /opt/CPshrd-R77/lib/libComUtils.so
    #7  0x... in T_event_mainloop_e () from /opt/CPshrd-R77/lib/libComUtils.so
    #8  0x... in T_event_mainloop () from /opt/CPshrd-R77/lib/libComUtils.so
    #9  0x... in fwm_cmain ()
    #10 0x... in fwmbin_cmain ()
    #11 0x... in main ()
    
Cause

The /var/log partition of the Security Management Server / Multi-Domain Security Management Server is full.


Solution