Support Center > Search Results > SecureKnowledge Details
"The changes you performed on this gateway cause it to no longer meet the requirements for participants in permanent tunnels" error when trying to edit the SmartLSM Profile object
Symptoms
  • Scenario:

    1. Create new SmartLSM Profile object:
      1. Right-click on 'Check Point' category - select 'SmartLSM Profile' - click on 'Small Office Appliance Gateway...'.
      2. Assign a name to the object.
      3. Make sure 'IPSec VPN blade' is enabled.
      4. Click on 'OK'.
    2. Open the properties of Star VPN community.
    3. Go to 'Tunnel Management' pane:
      1. Check the box 'Set Permanent Tunnels'
      2. Select the 'On all tunnels in the community'
      3. Check the box 'Enable Route Injection Mechanism (RIM)'
    4. Go to 'Satellite Gateways' pane:
      1. Click on 'Add...' button
      2. Select the new SmartLSM profile object
      3. Click on 'OK'
    5. Click on 'OK'.
    6. In the 'RIM - Compatibility' window, click on 'Yes'.
    7. Open the properties of the new SmartLSM profile object.
    8. Do not make any changes - click on 'OK'.
    9. The following error appears:
      The changes you performed on this gateway cause it to no longer
      meet the requirements for participants in permanent tunnels (see
      help for more details).
      
      Please correct these settings or cancel the operation.
      
    10. It is possible to edit the LSM profile object only after one of the following changes:
      • if LSM profile object is removed it from the 'Satellite Gateways' of Star VPN community
      • if the box 'Enable Route Injection Mechanism (RIM)' is cleared in Star VPN community properties
      • if the box 'Set Permanent Tunnels' is cleared in Star VPN community properties
Cause

The message incorrectly appears as an blocking Error instead of a Warning.


Solution
Note: To view this solution you need to Sign In .